A08F-G1A2
- FC-to-SATA RAID Subsystem
- High density, 8 drives in 2U rack space
- Auto switch cache policy and Auto shutdown
- Up to 64TB capacity per Logical Drive (LD) (OS dependent)
- Intelligent Drive Handling
Configuration | Model | Form Factor |
---|---|---|
Single | A08F-G1A2 | 2U Rackmount |
Specifications
RAID
- Multiple arrays configurable with dedicated or global hot spares
- RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
-
Online expansion by
- Adding new drives
- Copying and replacing drives with drives of larger capacity
- Automatic background rebuild
- Configurable stripe size and write policy per array
-
Intelligent Drive Handling
- In degraded mode: Skipping irreparable blocks to continue rebuild
- In normal operation: Data block verification and repair
System Components
Redundant, hot-swappable components, designed for no single point of failure
- 2U RAID enclosure
- Single RAID controller
- 8 drive trays
- Dual redundant power supplies
- 2 hot-swappable fan modules
Management
- Firmware-embedded Java-based GUI RAID manager
- Centralized management of multiple arrays over in-band or Ethernet
- Real-time event notification over Email, LAN broadcast, or SNMP traps
- Host-side SES emulation with pass-through to back-end I2C SES emulation
- SNMP 2.0 MIBs with get and set commands
- Firmware-embedded utility via LCD keypad or RS-232C port
Drive Interface
- Up to 1024 LUNs if sufficiently large memory is used with the proper settings
- 3.5", 1" high 1.5Gbps SATA disk drives
- 8 hot-swappable drive trays
- Automatic bad sector reassignment
- Drive hot-swappable via SCA-II connectors
- Dedicated bandwidth to each connected drive
Host Interface
- Auto-negotiate FC-AL, point-to-point, and switched fabric
- Concurrent I/O commands
- Tagged Command queuing up to 256
- Variable stripe size per logical drive
- Optimization setting for random or sequential I/Os
- Maintenance & Availability
- Immediate array availability
- Drive roaming, array configuration on drives
- Controller voltage and temperature self-diagnostics
- Auto switch cache policy and Auto shutdown
-
When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:
- Automatically flush cached data and switch the array’s caching mode from write-back to write-through
- Commence an auto shutdown
What is remarkable is all environmental thresholds associated with this mechanism are user-configurable and that caching mode changes back to write-back once normal condition is restored.
Physical/Electrical
Interfaces:
- 2 SFP sockets using a short-wavelength adapter
- One audio jack for RS-232C serial port (38400, n, 8, 1)
- One RJ-45 Ethernet port
Power supply:
- 2 redundant, hot-swappable power supplies with PFC
- Input: 90~260VAC, 47~63Hz
- Output: +5V, 25A max.; +12V, 24A max.; +3.3V, 20A max.; 350watts capacity
Cooling fan
- 2 cooling fans in two separate modules:
- Operating temperature: 5 to 40°C
- Non-operating temperature: - 40º to 60ºC
- Relative humidity: 10~95%, non-condensing
- Operating altitude: sea level to 10,000ft
Dimensions:
- Chassis dimensions: 88H x 446.2W x 486.5D mm
- (w/ protrusions): 88H x 481W x 525D mm
- Package dimensions: 344H x 600W x 670D mm
-
System weight (w/o drives):
- Net weight: 16kg
- Gross weight: 23.5kg